About Us

KEY WORDS

Computed tomography, measurement, artifacts, metrology.

ABSTRACT

Paper deals with medical and industrial tomography and describes they development, utilization and their basic functions and design principles. During sensing of object (patient) may occur artifacts caused by scanning object (body movement, implants, beam hardening). The paper describe the most frequently artifacts and compare the parameters of medical and industrial CT machines.

CITATION INFORMATION

Acta Mechanica Slovaca. Volume 17, Issue 4, Pages 40 – 47, ISSN 1335-2393

DOWNLOAD

  Computed Tomography – its Development, Principle and Image Artifacts

REFERENCES

[1]  Živčák, J., Hudák, R., Bednarčíková, L., Tóth, T., Trebuňová, M.: Biomechanizmy, implantáty na mieru, ISBN: 978-80-553-1396-2, s. 159, 2012

[2] Shampo, M. A., Kyle, R. A. Godfrey Hounsfield-developer of computed tomographic scanning. Mayo Clinic Proceeding, 71(10), p. 990, 1996
[3] Seynaeve, P. C., BROOS, J. I.: The history oftomography. Journal Belgede Radiologie. 78(5), p. 284-288, 1995
[4] Kalender, W. A.: Computed Tomography Fundamentals, System Technology, Image Quality, Applications. Munich: Publicis MCD, 220 p. ISBN 3-89578-081-2, 2000
[5] Reiser, M. F. et al.: Multislice CT. 3rd Ed. Berlin: Springer, 2009, 611 p. ISBN 978-3-540-33124-7. s. 5-10, 2009
[6] Fuchs, T., Kachelriess, M., Kalender, W. A.: Technical advances in multislicespiral CT. European Journal Of Radiology, 2000, 36 (2), s. 69-73, 2000
[7] Flohr, T. et al.: First performance evaluation of a dualsource CT (DSCT) system. European Radiology, 16 (2), p. 256-268, 2006
[8] Jhaveri, K., S. et al.: Effect of multislice CT technology on scanner productivity. American Journal of Roentgenology, 177(4),p. 769-772, 2001
[9] Endo, M et al.: Effect of scattered radiation on imagenoise in conebeam CT. Medical Physics, 28 (4), p. 469-474, 2001
[10] Gupta, R. et al.: Ultra highre solution flat-panel volume CT: fundamental principles, design architecture, and system characterization. European Radiology. 16(6), s.1191-1205, 2005
[11] Barrett, J. F., Keat, N.: Artifacts in CT: Recognition and Avoidance. Radio Graphics, 24 (6), p.1679–1691, 2004
[12] Barrett, J. F. et al.: Cardiac CT scanning. In MHRA Report 03076. [online]. London, England: Medicines and Healthcare Products Regulatory Agency, 2003. 36 p. [cit.2010.06.06] Dostupné na internete: http://www.cep.dh.gov.uk/. ISBN 1 84182 746 0, 2003
[13] Seeram, E.:Computed tomography: physical principles, clinical applications and quality control. 2nd ed. Philadelphia, Pa: Saunders, ISBN 9780721681733. p. 174-199, 2001

[14] Trebuňová, M, Dankovčík, R., Repovský A. a kol.: Artefakty pri zobrazovaní ultrazvukom, Folia Medica Cassoviensia, in press
[15] Živčák, J, Trebuňová, M, Repovský, A, Laputková, G.: Artefakty spôsobené pacientom pri zobrazovaní magnetickou rezonanciou. Lékař a technika - Clinician and technology, ISSN 0301-5491, 2(43), s. 17-22, 2013
[16] Živčák, J, Trebuňová, M, Repovský, A, Laputková, G.: Magnetic resonance image artifact due to the examination method and scanning sequences. Acta Mechanica Slovaca, ISSN 1335 - 2393, 17 (3), s.88-92, 2013
[17] Hudák, R., Živčák, J., Magin R.L.: Applications of Metrotomography in Biomedical Engineering In: Biomedical Engineering - Technical Applications in Medicine. - Rijeka: InTech, 2012 P. 225-244. - ISBN 978-953-51-0733-0

[18] Kruth, J.P., Bartscherb, M., Carmignatoc, S., Schmittd, R., De Chiffree, L., Weckenmannf, A.: Computed tomography for dimensional metrology, CIRP Annals - Manufacturing Technology, Volume 60, Issue 2, 2011, Pages 821–842
[19] Weiß, D., Shi Q., Kuhn Ch.: Measuring the 3D resolution of a micro-focus X-ray CT setup, http://www.ndt.net/article/ctc2012/papers/365.pdf
[20] Fedorko, G., Molnár, V., Marasová, D., Grinčová, A., Dovica, M., Živčák, J., Tóth, T., Husáková, N.: Failure analysis of belt conveyor damage caused by the falling material. Part 2: Application of computer metrotomography, In: Engineering failure analysis. Vol. 34 (2013), p. 431-442. - ISSN 1350-6307
[21] Fedorko, G., Molnár, V., Marasová, D., Grinčová, A., Dovica, M., Živčák, J., Tóth, T., Husáková, N.: Failure analysis of belt conveyor damage caused by the falling material. Part 1: Experimental measurements and regression models, In: Engineering failure analysis. Vol. 36 (2014), p. 30-38. - ISSN 1350-6307
[23] http://www.healthcare.siemens.com/
[24] www.gehealthcare.com/

Latest Issue

ams 2 2016

Download

Guests Online

We have 20 guests and no members online